Skip to content

Bafang DP E180.CAN

The Bafang DP E180.CAN is an e-bike display with storage from -20℃~60℃, a humidity range of 30%-70% RH, an operating range of -20℃~45℃ and an ingress rating of IPX5.

Last updated: 6 September 2026

What we found

  • Published as DP E180.CAN · IPX5 · -20℃~45℃.
  • 7 specifications are published for it, each with the source it was read from.
  • No matching recall was found in the records this catalogue holds from 8 regulators.

Assembled from the evidence on this page. Every figure and count below is shown with the source it was read from.

Frame and components

Assistance levels
Five levels, lit from the bottom up

“Power assistance indication (level 1 to level 5 is from bottom to top, no LED light means no power assistance)”

Source: bafang-e.com/uploaded/manual/BF-UM-C-DP E180-E181-EN.pdf

Storage temperature
-20℃~60℃

“Storage temperature: -20℃~60℃”

Source: bafang-e.com/uploaded/manual/BF-UM-C-DP E180-E181-EN.pdf

Humidity range Bafang give
30%-70% RH

“Bearing humidity: 30%-70% RH”

Source: bafang-e.com/uploaded/manual/BF-UM-C-DP E180-E181-EN.pdf

Ingress protection
IPX5

“Waterproof: IPX5”

Source: bafang-e.com/uploaded/manual/BF-DM-C-DP E180-E181-EN.pdf

Operating temperature
-20℃~45℃

“Operating temperature: -20℃~45℃”

Source: bafang-e.com/uploaded/manual/BF-UM-C-DP E180-E181-EN.pdf

Identity

Model name as declared
DP E180.CAN

“Model: DP E180.CAN”

Source: bafang-e.com/uploaded/manual/BF-DM-C-DP E180-E181-EN.pdf

Error codes

Error code table it publishes
Bafang's 31-code system table

“ERROR CODE DEFINITION The HMI can show the faults of Pedelec. When a fault is detected, the icon will be indicated and one of the following error codes will be indicated too.”

Source: bafang-e.com/uploaded/manual/BF-UM-C-DP E180-E181-EN.pdf

Models documented with this display

No model has been matched to this display yet in the records we hold. That is a statement about our research, not about which bikes carry it.